# IEmptyPageDetectionOptions

> Thresholds used to decide whether a page is empty — barcodes, black squares, text objects, and blackness percentage.

## What it does

Stores the options for detecting empty pages.

## Properties

Set any numeric threshold to `-1` to disable it.

| Name | Type | Access | Description |
| :- | :- | :- | :- |
| `KernelRect` | [IPageRect](/vantage/documentation/scanning-station/admin/i-page-rect) | Read/write | Relative rectangle of the page kernel, measured in twips. If all dimensions are `0`, the rectangle is defined automatically. |
| `MaxBarcodesCount` | `int` | Read/write | Maximum number of barcodes allowed on an empty page. |
| `MaxBlackSquaresCount` | `int` | Read/write | Maximum number of black squares allowed on an empty page. |
| `MaxTextObjectsCount` | `int` | Read/write | Maximum number of text objects allowed on an empty page. |
| `MaxBlacknessPercentage` | `int` | Read/write | Maximum blackness percentage allowed on an empty page. |

## Related topics

* [IPageInfo](/vantage/documentation/scanning-station/admin/i-page-info)